DC Shunt

DC Shunt 9230A Series

Current

Guildline Instruments

OVERVIEW

Low thermal effects and EMFs
Wide dynamic range
<10ppm long term stability
Air / oil cooled applications
Ranges from 10A to 10,000A

SPECIFICATION

Guildline’s 9230A Series of precision DC shunt standards are true 4 terminal devices intended for the precise measurement of DC current. They are constructed from specially selected materials supported on an insulating base for mechanical stability. 9230A shunts have a perforated metal cover to allow adequate cooling while providing physical protection to the instrument and operators.

DOWNLOADS

Application

National Measurement Institutes, Instrument Manufacturers, Calibration Laboratories, Pharmaceutical plants, Military

Excellent as a Precision DC Shunt Standards or Standard Resistor

Guildline Instruments 9230A series of precision DC current shunts/ standards are true 4-terminal devices intended for the precise measurement of DC current. They are constructed from specially selected elements supported on an insulating base for mechanical stability.

The 9230A DC shunt standards have a perforated metal cover to allow adequate cooling while providing physical protection for the elements and safety for the technician using the shunt. The design of the 9230A DC Shunt includes special features to reduce the effects of power dissipation and associated self heating errors. These DC shunts are designed to operate in air at full rated current.

The type of material selected for the elements has a very low temperature coefficient and the size and number of elements chosen give the optimum surface area to dissipate the power in air at the specified full scale current for a particular value. The performance of the 9230A DC shunts can be dramatically improved by operating them in a temperature controlled environment or immersing them in a stirred oil bath where power dissipation levels are less than 10 watts.

Interested in
this product?

Or speak to our expert UK-based team now
UK +44 (0)1264 316470 | US: +1 512 210 2288

Related Products

6640-Guildline

6640T Reference Thermometer Uncertainty up to +/- 0.01 ppm with 1mA

Temperature Bridge

Guildline Instruments

9334A-series

Resistance Air standard 9334A Stability at 2 ppm

Resistance Measurement

Guildline Instruments

Calibration Bath

Air Calibration Bath 5030

T° Bath

Guildline Instruments

5600

Liquid calibration bath 5600 Stability +/- 0.0015K (oil) and +/- 0.001K (water)

T° Bath

Guildline Instruments

We use cookies on this site to give you the very best user experience. Please choose one of the options: